BTU/hr.(For 115V/60Hz)
48.2 W or 164.4584
BTU/hr. (For 30V/50Hz)
300W:
50.4W or 171.9648
BTU/hr. (For115V/60Hz)
50.3W or 171.6236
BTU/hr.(For 230V/50Hz)
52W or 177.424
BTU/hr.(For 230V/50Hz)
51.4W or 175.3768
BTU/hr. (For 230V/50Hz)
53.3W or 181.8596
BTU/hr. (For 230V/50Hz)
System Heat Dissipation
with Energy Efficient
*
Power Supply
N/A N/A N/A N/A
Power Supply Fan
80mm variable speed 80mm variable speed 80mm variable speed 80mm variable speed
FEMP Standby Power
Compliant
(<2W in S5 - Power Off)
*
250W:
0.45W (For 115V/60Hz)
0.53W (For 230V/50Hz)
300W:
0.65W (For 115V/60Hz)
0.71W (For 230V/50Hz)
0.61W (For 115V/60Hz)
0.69W (For 230V/50Hz)
0.26W (For 115V/60Hz)
0.30W (For 230V/50Hz)
0.42W (For 115V/60Hz)
0.47W (For 230V/50Hz)
Power Consumption in ES
Mode - Suspend to RAM
(S3) (Instantly Available
PC)
<3W <3W <1W <3W
High voltage immunity
up to 410V/s
N/A
up to 410V/s
N/A
China Telecom YD/T 993-
2006 spec
Yes
N/A
Yes
N/A
System Environmental
Specs
Values are subject to change without notification and are for reference only.
Performance of system, options, and ancillary equipment will vary depending on the system
configuration.
Levels presented do not account for non-HP/Compaq installed hardware.
Ambient Air Temperature
Operating
MT: Operating 41° to 95°F (5 to 35°C) (Test 0 to
104°F (40°C));
SFF: 50° to 95°F (10° to 35°C) at sea level with an
altitude de-rating of 1.0°C per every 1000 ft (300
m) above sea level to a maximum of 10000 ft
(3048 m), no direct sustained sunlight. Maximum
rate of change is 50°F/Hr (10°C/Hr). The upper
limit may be limited by the type and number of
options installed.
Storage
MT: Storage: 90% RH @ 60°C for 12 hours (Non-
condensing)
SFF: -22° to 140°F (-30° to 60°C).
Humidity
Operating
MT: 10% to 90% relative humidity (Rh), 35°C non-
condensing
SFF: 10% to 90% relative humidity (Rh), 35°C
maximum wet bulb temperature, non-condensing
QuickSpecs
HP Pro 3000 Business PC
System Details
DA - 13483 North America — Version 8 — March 7, 2011
Page 12