System Unit
Dimensions
(H x W x D)
8 SFF
1.7 x 17.11 x 27.5 inches (4.32 x 43.46 x 69.90
cm)
4 LFF
1.7 x 17.11 x 29.5 inches (4.32 x 43.46 x 75.0 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supply, and processor
installed)
8 SFF/4 LFF - 16.2/16.8 kg, 35.7/37.0 lb
Minimum
(one hard drive, power
supply, and processor
installed)
8 SFF/4 LFF - 10.9/11.9 kg, 24.0/26.2 lb
Input Requirements
(HP ProLiant 350 W power
supply)
Rated Line Voltage
100 to 120 VAC
Rated Input Current
6 Amps (at 100VAC) to 3 Amps (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Power Supply Output
(per power supply)
Rated Steady-State Power
350 W (at 100 to 120 VAC),
350 W (at 200 to 240 VAC)
Maximum Peak Power
400 W (at 100 to 120 VAC),
400 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
QuickSpecs
HP ProLiant DL320e Generation 8 (Gen8)
Technical Specifications
DA - 14326 North America — Version 5 — November 17, 2012