Removal and replacement procedures 56
11.
Install all power supplies ("Hot-plug power supply" on page 30).
12. Install the air baffle ("Air baffle" on page 37).
13. Install the BBWC battery pack, if removed ("BBWC battery pack" on page 36).
14. Install the access panel ("Access panel" on page 27).
15. Install the server into the rack.
16. Slide the server into the rack.
17. Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Serial Number. The following warning is displayed:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
4. Press the Enter key to clear the warning.
5. Enter the serial number.
6. Select Product ID. The following warning is displayed.
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
7. Enter the product ID and press the Enter key.
8. Press the Esc key to close the menu.
9. Press the Esc key to exit RBSU.
Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
HP Trusted Platform Module
The TPM is not a customer-removable part.
CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to
ensure the integrity of the system data.
If you suspect a TPM board failure, leave the TPM installed and remove the system board ("System board"
on page 51). Contact an HP authorized service provider for a replacement system board and TPM board.