Removal and replacement procedures  18 
3. 
Remove the optical device. 
 
To replace the drive, slide the drive into the bay until it clicks. 
 
Optical device ejector 
1.  Power down the server ("Powering down the server" on page 11). 
2.  Remove all hard drives ("Hard drive" on page 14) and the hard drive blank (on page 13). 
3.  Eject the optical device (on page 17) or optical device blank. 
4.  Extend or remove the server from the rack ("Extending the server from the rack" on page 11). 
5.  Remove the diskette drive ("Diskette drive" on page 16). 
6.  Use a T-10 Torx screwdriver to remove the screws that secure the optical device ejector to the server 
chassis. 
7.  Press the tab on the side of the optical device ejector to release it from the chassis. 
8.  Remove the optical device ejector.