Removal and replacement procedures 20
6.
Remove the component from the server.
CAUTION: When replacing the component, be sure the power converter module is properly seated in the
server chassis.
To replace the component, reverse the removal procedure.
Processor fan assembly
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
To remove the component:
1. Extend or remove the server from the rack ("Extending the server from the rack" on page 11).
2. Remove the access panel ("Removing the access panel" on page 13).
3. Loosen the thumbscrew that secures the processor fan assembly to the server.
4. Push on the sheet metal tab near the thumbscrew to separate the fan tray connector from the system
board connector.