Hardware options installation 51
8.
Install the drives ("Drive options" on page 36).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
9. Power up the server (on page 20).
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (http://www.hp.com/support/CASAC_RG_en).
Installing the FBWC module and capacitor pack
1. Power down the server (on page 20).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 20).
o Remove the server from the rack (on page 22).
4. Remove the access panel (on page 23).
5. Do one of the following:
o If you are installing the cache module on the system board or in a storage controller installed in the
primary PCI riser cage, remove the primary PCI riser cage ("Remove the PCI riser cages" on page
25).
o If you are installing the cache module on a storage controller installed in the optional secondary PCI
riser cage, remove the secondary PCI riser cage ("Remove the PCI riser cages" on page 25).
CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the
cache module and cable are susceptible to damage. Avoid excessive force and use caution to
avoid damage to these connectors.