Diagnostic tools 56
•
If the diskette is valid, the server generates one long beep and two short beeps to indicate that
the server is in disaster recovery mode.
• If the diskette is invalid or not inserted, the server continues to beep.
5. Wait while the ROMPaq diskette flashes the system ROM image:
• If successful, the server generates a sequence of ascending audible beeps.
• If unsuccessful, the server generates a sequence of descending audible beeps. Repeat the
disaster recovery process.
6. Power down the server (on page 25).
7. Remove the ROMPaq diskette.
8. Power up the server.
Manual ROMPaq disaster recovery
1. Create a ROMPaq diskette using the Autorun Menu on the SmartStart CD.
2. Power down the server (on page 25).
3. Insert the ROMPaq diskette.
4. Set S1, S4, S5, and S6 of the system maintenance switch to On ("System board components" on
page 61).
5. Power up the server.
• If the diskette is valid, the server generates one long beep and two short beeps to indicate that
the server is in disaster recovery mode.
• If the diskette is invalid or not inserted, the server continues to beep.
6. Wait while the ROMPaq diskette flashes the system ROM image:
• If successful, the server generates a sequence of ascending audible beeps.
• If unsuccessful, the server generates a sequence of descending audible beeps. Repeat the
disaster recovery process.
7. Power down the server (on page 25).
8. Remove the ROMPaq diskette.
9. Set S1, S4, S5, and S6 of the system maintenance switch to Off.
10. Power up the server.