Specifications 83
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10° C to 35° C (50° F to 95° F)
Nonoperating
-30° C to 60° C (-22° F to 140° F)
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1° C per 304.8 m (1.8° F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification Tower model Rack model
Height
36.82 cm (14.50 in) 17.50 cm (6.89 in)
Depth
47.52 cm (18.71 in) 47.52 cm (18.71
in)
Width
17.50 cm (6.89 in) 36.82 cm (14.50
in)
Weight, minimum with SFF drive cage
11.00 kg (24.22 lb) 11.00 kg (24.22
lb)
Weight, maximum with SFF drive cage
17.00 kg (37.44 lb) 17.00 kg (37.44
lb)
Weight, minimum with LFF drive cage
11.90 kg (26.21 lb) 11.90 kg (26.21
lb)
Weight, maximum with LFF drive cage
19.00 kg (41.85 lb) 19.00 kg (41.85
lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP 350 W 4U Integrated Power Supply
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)