Removal and Replacement Procedures
To replace removable media devices, other than HP StorageWorks AIT or SDLT tape drives,
insert the device into the bay until it clicks into place.
CAUTION: Install all other options and blanks prior to installing the tape drive.
CAUTION: If you are replacing HP StorageWorks AIT or SDLT tape drives, be sure to
replace the left rear mounting screw with a Torx T-8 drive screw. Failure to do so prevents
proper installation and can damage the tape drive.
NOTE: It is not necessary to push up on the drivelock when installing a removable media device.
To replace HP StorageWorks AIT or SDLT tape drives:
1. Replace the left rear mounting screw with a Torx T-8 drive screw, included in the tape
drive kit.
2. Insert the device into the bay until the device clicks into place.
1
2
Figure 2-23: Replacing the tape drive
2-26 HP ProLiant ML350 Generation 3 Server Maintenance and Service Guide