Physical and Operating Specifications
System Unit
Table 5-1: System Unit Specifications
Item Description
Height (without feet) 44.5 cm (17.5 in)
Height (with feet) 46.99 cm (18.5 in)
Depth (without bezel) 60.96 cm (24.0 in)
Depth (with bezel) 66.04 cm (26.0 in)
Width (without feet) 21.59 cm (8.5 in)
Width (with feet) 26.04 cm (10.25 in)
Weight (no drives installed) 27.24 kg (60.0 lb)
Input requirements International Units (English Units)
Rated input voltage 200 VAC to 240 VAC (100 VAC to 120 VAC)
Rated input frequency 50 Hz to 60 Hz
Rated input current 3.7 A (7.4 A)
Rated input power 538 W
BTUs per hour 1,839
Power supply output
Rated steady-state power 500 W
Temperature range
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Relative humidity (noncondensing)
Operating 10% to 90%
Nonoperating 5% to 95%
Wet-bulb temperature
Maximum
28°C (82.4°F)
Acoustic noise
Idle (hard drives spinning) 6.2 NPEL (BELS)/45 AVERAGE SPL (dba)
Operating (random seeks to hard drives) 6.8 NPEL (BELS)/49 AVERAGE SPL (dba)