Troubleshooting 173
Logical Drive X Status = Overheating .......................................................................................189
Logical Drive X Status = Recovering (rebuilding data on a replaced drive) .............................190
Logical Drive X Status = Wrong Drive Replaced......................................................................190
Loose Cable Detected - Logical Drives May Be Marked FAILED Until Corrected..................190
Mirror Data Miscompare............................................................................................................190
No Configuration for Array Accelerator Board..........................................................................191
NVRAM Configuration Present, Controller not Detected..........................................................191
One or More Drives is Unable to Support Redundant Controller Operation .............................191
Other Controller Indicates Different Hardware Model...............................................................191
Other Controller Indicates Different Firmware Version.............................................................191
Other Controller Indicates Different Cache Size........................................................................192
RIS Copies Between Drives Do Not Match ...............................................................................192
SCSI Port X Drive ID Y failed - REPLACE (failure message) .................................................192
SCSI Port X, Drive ID Y Firmware Needs Upgrading ..............................................................192
SCSI Port X, Drive ID Y Has Exceeded the Following Threshold(s)........................................193
SCSI Port X, Drive ID Y is not Stamped for Monitoring...........................................................193
SCSI Port X, Drive ID Y May Have a Loose Connection... ......................................................193
SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match ..................................194
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in the
Factory Monitor and Performance Data... ..................................................................................194
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in the
Power Monitor and Performance Data... ....................................................................................194
SCSI Port X, Drive ID Y Was Replaced On a Good Volume: (failure message) ......................194
Set Configuration Command Issued...........................................................................................195
Soft Firmware Upgrade Required...............................................................................................195
Storage Enclosure on SCSI Bus X has a Cabling Error (Bus Disabled)... .................................195
Storage Enclosure on SCSI Bus X Indicated a Door Alert.........................................................195
Storage Enclosure on SCSI Bus X Indicated a Power Supply Failure... ....................................195
Storage Enclosure on SCSI Bus X Indicated an Overheated Condition.....................................196
Storage Enclosure on SCSI Bus X is Unsupported with its Current Firmware Version... .........196
Storage Enclosure on SCSI Bus X Indicated that the Fan Failed...............................................196
Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded......................................197
Storage Enclosure on SCSI Bus X Indicated that the Fan Module is Unplugged... ...................197
Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed...............................................197
Swapped Cables or Configuration Error Detected. A Configured Array of Drives... ................197
Swapped Cables or Configuration Error Detected. A Drive Rearrangement... ..........................198
Swapped Cables or Configuration Error Detected. An Unsupported Drive Arrangement Was
Attempted... ................................................................................................................................198
Swapped Cables or Configuration Error Detected. The Cables Appear To Be Interchanged....199
Swapped Cables or Configuration Error Detected. The Configuration Information on the