QuickSpecs
hp AlphaServer SC20
DA-10976 North America — Version 1 — May 24, 2002 30
Technical Specifications
Air Flow and Quality
Intake location Front
Interconnect Building Blocks
(continued)
Exhaust location Rear
Particle size N/A
Concentration N/A
Altitude
Operating* 10,000 ft/3,048 m
Non-operating 40,000 ft/12,192 m
NOTE: * Higher altitudes are possible if maximum operating temperature is reduced
(see Temperature); other restrictions may apply, such as maximum
permissible altitude for hard drives.
Vibration
Operating 10 to 500 Hz 0.1 G peak
Non-operating 1.03 Grms 5-300 Hz
ELECTRICAL (Power supplies are universal, PFC, auto ranging, 100/240 VAC)
Nominal Voltage (VAC)
200 to 240
Voltage Range (VAC)
temporary condition
180 to 250
Power Source Phase
Single
Nominal Frequency (Hz)
50/60
Frequency Range (Hz)
49 to 51/59 to 61
RMS Current
(maximum steady state):
Each power cord 16 A
Power Cords Agency Approvals (Series EA2008)
UL: Listed to UL1950 (third edition)
UL/CNL: Certified to CAN/CSA-C22.2 No.
950-M93
FCC: Part 15.B Class A
CE: EN55022, EN55024, EN61000-3-2,
EN61000-3-3
VCCI V-3/97.04 Class A
BSMI: CNS13438
C-Tick: AS/NZS 3548: 1995 Class A
Reviewed to AS/NZ 3260:1993 Australian/New Zealand
Standard
EN60950/A11:1997 European Norm
IEC 950 (second edition, second amend)
Number of Power Cords
DA-SCBPA-AA/AB 4
DA-SCCAA-DA/DB 3