SolutionClosed defect summary
Fixed in Fabric OS 6.1.1c.Panic occurs with switch in Access Gateway Mode when N_Port to
F_Port trunking is enabled.
Fixed in Fabric OS 6.1.1c.Unexpected return code from Fast Write and Tape Pipelining
causes GE_Port traffic interrupt.
Fixed in Fabric OS 6.1.1c.When first upgrading a newly installed Fabric OS 6.0.x director to
Fabric OS 6.1.x, there is a very small window that 8-Gb blades may
fault.
Fabric OS 6.1.1d fixes
Table 13 lists defects closed in the Fabric OS 6.1.1d firmware release.
Table 13 Fabric OS 6.1.1d closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.1.1d.
Workaround: Before upgrading to
6.1.1d, perform portdisable /
portenable on the device port to
regain the host/device connection.
After multiple controller reboots, PLOGI Accept is dropped due to
missing CAM entry.
Fixed in Fabric OS 6.1.1d.VI to PT routes are deleted following portdisable/portenable
on HP StorageWorks SAN Director 48 Port FC blade.
Fixed in Fabric OS 6.1.1d.Switch may experience timeouts and traffic interruption during HCL
operation of neighboring switch with Fabric OS 6.2.0.
Fixed in Fabric OS 6.1.1d.Observed kernel panic on HP StorageWorks DC SAN Director, in RTE
module.
Fixed in Fabric OS 6.1.1d.During HA recovery, Fabric Watch failed to initialize on fully populated
Brocade DCX. Reports switch health status as Marginal/Down. Traffic
is not impacted, but DCFM call home will not be initiated.
Fixed in Fabric OS 6.1.1d.License database can be corrupted after configdonwload and can
not be added back. 4G platform can disable QoS but cannot enable
QoS without license.
Fixed in Fabric OS 6.1.1d.Customer may experience high CPU load and unexpected blade errors
due to issue responding to ASIC generated interrupts.
Fixed in Fabric OS 6.1.1d.Some OS/HBA combinations take down FC link when N_Port gener-
ated RSCNs are delivered by switch with 0x08 (Fabric OS 6.1.1b &
6.1.0g) or 0x20 (6.1.0x) as event qualifier. Fix reverts back to Fabric
OS 6.0 value of 0x00.
Fixed in Fabric OS 6.1.1d.WebTools GUI freezes a few seconds about every 15 seconds.
WebTools light stops blinking, and cannot scroll any windows.
26

Other manuals for HP StorageWorks 8/24 - SAN Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 8/24 - SAN Switch and is the answer not in the manual?

HP StorageWorks 8/24 - SAN Switch Specifications

General IconGeneral
BrandHP
ModelStorageWorks 8/24 - SAN Switch
CategorySwitch
LanguageEnglish

Related product manuals