Fixed in Fabric OS 6.2.0.
Trying to enable a LUN on a member node fails stating Specified
target not hosted by local node.
Fixed in Fabric OS 6.2.0.
Configdownload fails for fdd.* parameters from Fabric OS 6.1.1
to 6.2.0 through CAL.
Fixed in Fabric OS 6.2.0.
With default zoning set to All Access, ACK frame with FC_type Exten-
ded Link can be dropped.
Fabric OS 6.2.0a fixes
The following table lists defects closed in the Fabric OS 6.2.0a firmware release.
Table 9 Fabric OS 6.2.0a closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.2.0a.
In a B2E routed environment, when the user executes the Pathinfo
command in BB querying for xlate domain, the switch may panic.
Fixed in Fabric OS 6.2.0a.
Some OS/HBA combinations take down the FC link when N_Port-
generated RSCNs are delivered by switch with 0x08 (Fabric OS 6.1.1b
and 6.1.0g) or 0x20 (6.1.0x) as event qualifier. The fix reverts back
to Fabric OS 6.0 value of 0x00.
Fixed in Fabric OS 6.2.0a.
Switches slowly leaked memory over an extended period while being
managed by DCFM.
Fabric OS 6.2.0b fixes
The following table lists defects closed in the Fabric OS 6.2.0b firmware release.
Table 10 Fabric OS 6.2.0b closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.2.0b.
CUP can fail to send CU-End to clear busy. CUP is still responsive, but
the host is waiting for the CUE.
Fixed in Fabric OS 6.2.0b.
WWN card FRU replacement does not send async reports to FICON
host, so that customers do not know when a WWN card has been
removed.
Fixed in Fabric OS 6.2.0b.
Customers may experience high CPU load and unexpected blade errors
due to an ASIC-generated interrupt handling problem.
Fixed in Fabric OS 6.2.0b.
Unable to configure ports using configdownload if the ports are
not physically present in the director (blade not plugged in).
Workaround prior to upgrade: Do not
change VF mode until dual CP chassis
is in sync
Fixed in Fabric OS 6.2.0b.
.
On HP StorageWorks DC SAN Director, after running fosconfig
--enable vf, followed by fosconfig --disable vf, customer
cannot log in via Telnet or serial port, and a Cannot assign valid
AD at the login session error occurs.