HP VS17 Service Manual
54
7. Repeat above procedure ( item 4,5,6) until chroma 7120 RGB value meet the
tolerance =100±2
B. Adjust SGB color-temperature
1. Switch the chroma-7120 to RGB-Mode (with press “MODE” button )
2. Switch the MEM .Channel to Channel 4( with up or down arrow on chroma 7120 )
3. The LCD-indicator on chroma 7120 will show x = 313 ±10, y = 329 ±10,
Y = 210 ±10 cd/m
2
4. Adjust the RED of color3 on factory window until chroma 7120 indicator reached
the value R=100
5. Adjust the GREEN of color3 on factory window until chroma 7120 indicator
reached the value G=100
6. Adjust the BLUE of color3 on factory window until chroma 7120 indicator reached
the value B=100
7. Repeat above procedure ( item 4,5,6) until chroma 7120 RGB value meet the
tolerance =100±2
C. Press reset key and Turn the Power-button “off to on” to quit from factory mode.
11. EDID CONTENT
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
0 00 FF FF FF FF FF FF 00 22 F0 47 26 01 01 01 01
16 20 0E 01 03 68 22 1B 8C EE 2D 90 A4 57 4A 9C 25
32 11 50 54 AD EF 80 81 80 01 01 01 01 01 01 01 01
48 01 01 01 01 01 01 30 2A 00 98 51 00 2A 40 30 70
64 13 00 54 0E 11 00 00 1E 00 00 00 FD 00
32
4C 1E
80 53 0E 00 0A 20 20 20 20 20 20 00 00 00 FC 00 68
96
70 20 76 73 31 37 0A 20 20 20 20 20 00 00 00 FF
112
00 43 4E 43 34 33 32 30 30 30 31 0A 20 20 00 74