No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
setting 2
Group F06 MS SPEED and Simple PLC (refer to pages 74
78)
F06.00
Multi-step frequency
command 1
F00.09-upper limit 3.00Hz 0.01Hz ○
F06.01
Multi-step frequency
command 2
F00.09-upper limit 6.00Hz 0.01Hz ○
F06.02
Multi-step frequency
command 3
F00.09-upper limit 9.00Hz 0.01Hz ○
F06.03
Multi-step frequency
command 4
F00.09-upper limit 12.00Hz 0.01Hz ○
F06.04
Multi-step frequency
command 5
F00.09-upper limit 15.00Hz 0.01Hz ○
F06.05
Multi-step frequency
command 6
F00.09-upper limit 18.00Hz 0.01Hz ○
F06.06
Multi-step frequency
command 7
F00.09-upper limit 21.00Hz 0.01Hz ○
F06.07
Multi-step frequency
command 8
F00.09-upper limit 24.00Hz 0.01Hz ○
F06.08
Multi-step frequency
command 9
F00.09-upper limit 27.00Hz 0.01Hz ○
F06.09
Multi-step frequency
command 10
F00.09-upper limit 30.00Hz 0.01Hz ○
F06.10
Multi-step frequency
command 11
F00.09-upper limit 33.00Hz 0.01Hz ○
F06.11
Multi-step frequency
command 12
F00.09-upper limit 36.00Hz 0.01Hz ○
F06.12
Multi-step frequency
command 13
F00.09-upper limit 39.00Hz 0.01Hz ○
F06.13
Multi-step frequency
command 14
F00.09-upper limit 42.00Hz 0.01Hz ○
F06.14
Multi-step frequency
command 15
F00.09-upper limit 45.00Hz 0.01Hz ○
F06.15
Simple PLC control
selection
0: No PLC operation
1: Enabling PLC operation
0 1 ×
F06.16
Simple PLC operation
mode selection
Units: PLC operation mode
selection
0: Stop after single cycle
operation
1: Maintain the final value
after single cycle of PLC
operation
2: Cycle operation
Tens: PLC operation restart
mode selection after pause
0000 1 ×