Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual -153-
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
10
F06.38 Running time of step 11 0.0-3276.7 0.0 0.1 ○
F06.40
Running time of step
12
0.0-3276.7
0.0 0.1 ○
F06.42
Running time of step
13
0.0-3276.7
0.0 0.1 ○
F06.44
Running time of step
14
0.0-3276.7
0.0 0.1 ○
F06.46
Running time of step
15
0.0-3276.7
0.0 0.1 ○
Group F07 Wobble Operation Parameters (refer to pages 78
80)
F07.00
Wobble operation
selection
0: Disabled
1: Enabled
0 1 ×
F07.01
Wobble operation
mode
Units: Start mode of wobble
operation
0: Auto start (according to
F07.03)
1: Manual start
Tens: Wobble operation
amplitude
0: Relative to the wobble
central frequency
1: Relative to the maximum
output frequency
Hundreds: Restart mode of
wobble operation
0: The inverter restarts the
wobble operation as per the
recorded frequency and
direction when it stops last
time
1: The inverter restarts the
wobble operation from 0 Hz
Thousands: Save the wobble
operation parameters at
power outage
0: Saved
1: Not be saved
0000 1 ×
F07.02
Preset wobble
frequency
0.00-upper limit 0.00Hz 0.01Hz ×
F07.03
Holding time of preset
wobble frequency
0.0-999.9s 0.0s 0.1s ×
F07.04 Wobble amplitude 0.0-50.0% 0.0% 0.1% ×
A