Chapter 7 Troubleshooting Shenzhen Hpmont Technology Co., Ltd
126 HD30 Series Inverters User Manual
Fault code Fault name Possible reasons of fault Counter-measures
E0025
PID reference
loss
Analogue reference signal is
smaller than F20.12
Analogue input circuit fault
Please check the connection
Please seek technical support
E0026 PID feedback loss
Analogue setting signal is
smaller than F20.14
Analogue input circuit fault
Please check the connection
Please seek technical support
E0027
PID feedback out
of limiting
Analogue setting signal is
bigger than F20.16
Analogue input circuit fault
Please check the connection
Please seek technical support
E0028
SCI
communication
time-out
Connection fault of
Communication cable
Disconnected or not well
connected
Please check the connection
E0029
SCI
communication
error
Connection fault of
Communication cable
Disconnected or not well
connected
Communication setting error
Communication data error
Please check the connection
Please check the connection
Please correctly set the
communication format (F17.00)
and the baud rate (F17.01)
Send the data according to
MODBUS protocol

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD30-4T022G/030P and is the answer not in the manual?

hpmont HD30-4T022G/030P Specifications

General IconGeneral
Brandhpmont
ModelHD30-4T022G/030P
CategoryInverter
LanguageEnglish

Related product manuals