Do you have a question about the HT COMBI419 and is the answer not in the manual?
Continuity Test | Yes |
---|---|
Diode Test | Yes |
DC Current | 10A |
AC Current | 10A |
Resistance | 40MΩ |
Frequency | 10Hz-10MHz |
Display | 4000 counts |
Standard | IEC/EN61010-1 |
Safety | CAT III 600V |
Operating Temperature | 0°C |
Dimensions | 40mm |
Safe usage instructions before and during measurement.
Recommendations and instructions for safe operation while using the instrument.
Instructions for powering off and storing the instrument after use.
Defines measurement categories (IV, III, II, I) per overvoltage standards.
Introduces the instrument and its covered models.
Lists the tests the instrument can perform.
Recommends checking the instrument for transport damage and package contents.
Details battery power, charge indication, and auto power-off features.
States warranty period for technical specifications.
Recommends returning the instrument to normal conditions after long storage.
Identifies front, upper, and side parts of the instrument with captions.
Explains how to use and the battery impact of display backlighting.
Lists and describes the function of each key on the instrument.
Describes the graphic module display and its elements.
Details information shown on the initial screen when turning on the instrument.
Explains how to access measurements listed between AUTO and PWR.
Describes how to access and modify instrument settings.
How to select the instrument's display language.
How to enable/disable the auto power off feature.
How to set the nominal voltage for calculations.
How to set the mains frequency.
How to select the type of electric power supply system.
Accesses memory management functions.
Performs an automatic sequence of tests: earth resistance, RCD tripping, insulation resistance.
Measures continuity of earth conductors with test current > 200mA.
Measures insulation resistance between conductors and earth.
Tests tripping time and current of system RCDs.
Measures line/loop impedance and calculates prospective short circuit current.
Measures total earth resistance with 15mA without tripping RCD.
Tests phase sequence by direct contact with live parts.
Measures environmental parameters using external transducers.
Measures acoustic pressure (SPL, Peak, Duration) using sound level probe.
Measures air speed, humidity, temperature, and light using probes.
Describes anomalous results for AIR, RH, TMP, Lux, VOLT modes.
Measures leakage current in real-time using an external clamp.
Measures mains voltage, current, harmonics, power, and power factor.
Measures electrical parameters like current, voltage, power, PF.
Measures voltage and current harmonics.
Instructions on how to save measured data.
Manages saved measurements, including recall and deletion.
Steps to display saved measurements.
Options to delete single or all stored measurements.
Describes what happens when memory is accessed with no saved data.
General recommendations for instrument use and storage.
Step-by-step guide for replacing instrument batteries.
Instructions for cleaning the instrument.
Symbol indication for proper disposal of equipment.
Detailed technical specifications for various measurement functions.
Lists safety standards and specifications for the instrument.
General safety ratings, pollution level, and overvoltage category.
Lists standards for different measurement types.
Standard for sound level measurement.
Mechanical data, power supply, display, memory, PC interface.
Environmental working conditions.
Specifies temperature, humidity, and altitude limits.
Refers to the packing list for accessories.
Outlines warranty terms, exclusions, and manufacturer rights.
Troubleshooting steps and return procedure for service.
Purpose, installation parts, and allowable values for continuity tests.
Purpose and example of insulation resistance measurement.
Definitions, purpose, and allowable values for checking circuit separation.
Purpose, parts, allowable values, and notes for testing RCDs.
Purpose, installation parts, allowable values, and notes for testing RCD tripping current.
Purpose, installation parts, and allowable values for short-circuit impedance.
Purpose, installation parts, and allowable values for fault loop impedance.
Purpose, installation parts, and allowable values for earth resistance in TT systems.
Theory, limit values, causes, and consequences of voltage and current harmonics.
Definitions and conventions for power and power factor.