Part 1 - General Safety Information
This appliance is approved for indoor installations only and is
not intended for use as a pool heater. Clearance to combustible
materials: 0” top, bottom, sides, and back. Appliance must have
room for service: 24” front and 12” sides are minimum recommended
service clearances. (A combustible door or removable panel is
acceptable front clearance.) This appliance has been approved for
closet installation and installation on combustible ooring. Do not
install directly on carpeting. Install the appliance in a location where
temperature and pressure relief valve discharge or a leak will not
result in damage to the surrounding area. If such a location is not
available, install an auxiliary catch pan. Use only Category IV vent
systems.
Installer - Read all instructions in this manual before installing.
Perform steps in the given order.
User - This manual is for use only by a qualied heating installer
/ service technician. Have this appliance serviced / inspected
annually by a qualied service technician.
FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE
CAN RESULT IN SUBSTANTIAL PROPERTY DAMAGE, SEVERE
PERSONAL INJURY, OR DEATH.
NOTE: Obey all local codes. Obtain all applicable permits before
installing the appliance.
NOTE: Install all system components and piping in such a manner
that does not reduce the performance of any re rated assembly.
Part 14 - Installation Checklist 48
Part 15 - Maintenance Report 49
Part 16 - Replacement Parts 51
Limited Warranty 54
Maintenance Notes 56
Customer Installation Record Form 57
NOTE: If the appliance is exposed to the following, do not operate.
Immediately call a qualied service technician.
1. Fire
2. Damage
3. Water
Failure to follow this information could result in property damage,
severe personal injury, or death.
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN
SUBMERGED IN WATER. Immediately call a qualied service
technician. The appliance MUST BE replaced if it has been
submerged. Attempting to operate a appliance that has been
submerged could create numerous harmful conditions, such as
a potential gas leakage causing a re and/or explosion, or the
release of mold, bacteria, or other harmful particulates into the
air. Operating a previously submerged appliance could result in
property damage, severe personal injury, or death.
NOTE: Appliance damage due to ood or submersion is considered
an Act of God, and IS NOT covered under product warranty.
Altering any HTP, Inc. appliance with parts not manufactured by
HTP, Inc. WILL INSTANTLY VOID the appliance warranty and could
result in property damage, personal injury, or death.
High heat sources (sources generating heat 100
o
F / 37
o
C or greater,
such as stove pipes, space heaters, etc.) may damage plastic
components of the appliance as well as plastic vent pipe materials.
Such damages ARE NOT covered by warranty. It is recommended to
keep a minimum clearance of 8” from high heat sources. Observe heat
source manufacturer instructions, as well as local, state, provincial,
and national codes, laws, regulations and ordinances when installing
this appliance and related components near high heat sources.
A. Improper Combustion
Do not obstruct the ow of combustion and ventilating air. Adequate
air is necessary for safe operation. Failure to keep the exhaust vent
and combustion air intake clear of ice, snow, or other debris could
result in property damage, serious personal injury, or death.
B. Gas
Should overheating or gas supply fail to shut o, turn o the manual
gas control valve to the appliance.
C. When Servicing the Appliance
To avoid electric shock, disconnect electrical supply before performing
maintenance.
NOTE: When inquiring about service or troubleshooting, reference the
model and serial numbers from the appliance rating label.
To avoid severe burns, allow appliance and associated equipment to
cool before servicing.
Be sure to disconnect electrical power before performing service.
Failure to do so could result in electrical shock, property damage,
serious personal injury, or death.
D. Appliance Water
Do not use petroleum-based cleaning or sealing compounds in a water
heating system. Gaskets and seals in the system may be damaged. This
can result in substantial property damage.
Do not use “homemade cures” or “patent medicines. Damage to the
appliance, substantial property damage, and/or serious personal
injury may result.
E. Freeze Protection
NOTE: Consider piping and installation when determining appliance
location.
Failure of the appliance due to freeze related damage IS NOT covered
by product warranty.
NEVER use any toxic chemical, including automotive, standard glycol
antifreeze, or ethylene glycol made for hydronic (non-potable)
systems. These chemicals can attack gaskets and seals in water
systems, are poisonous if consumed, and can cause personal injury
or death.
Do not use this appliance for anything other than its intended
purpose (as described in this manual). Doing so could result in
property damage and WILL VOID product warranty.
UNCRATING THE APPLIANCE - Any claims for damage or shortage
in shipment must be led immediately against the transportation
company by the consignee.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HTP Versa Hydro PHE130 Series and is the answer not in the manual?

HTP Versa Hydro PHE130 Series Specifications

General IconGeneral
BrandHTP
ModelVersa Hydro PHE130 Series
CategoryHeater
LanguageEnglish

Related product manuals