EasyManua.ls Logo

Huawei AR1200 Series - Page 187

Huawei AR1200 Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 7-6 Description of 150 W DC power indicators
Name Status Description
STATU
S
Off
l The input power is out of range, for example, no DC input
power, DC input overvoltage, and DC input undervoltage.
l The output power is out of range, for example, undervoltage
or overtemperature occurs.
Green The DC input power is within range.
Blinking green The output power is out of range, for example, overvoltage,
overcurrent, or short circuit occurs.
PWR350D
Figure 7-8 shows the indicator of the PWR350D.
Figure 7-8 Indicator of the PWR350D
Indicator
Table 7-7 Description of the PWR350D indicators
Name
Status Description
STATUS Off
l The input power is out of range, for example, no DC
input power, DC input overvoltage, and DC input
undervoltage.
l The output power is out of range, for example,
undervoltage or overtemperature occurs.
Green The DC input power is within range.
Blinking green The output power is out of range, for example,
overvoltage, overcurrent, and short circuit occurs.
PWR150A
Figure 7-9 shows the indicator of the PWR150A.
Huawei AR1200&2200&3200 Series Enterprise Routers
Hardware Description 7 List of Indicators
Issue 03 (2012-04-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
180

Table of Contents

Other manuals for Huawei AR1200 Series

Related product manuals