Table 7-6 Description of 150 W DC power indicators
Name Status Description
STATU
S
Off
l The input power is out of range, for example, no DC input
power, DC input overvoltage, and DC input undervoltage.
l The output power is out of range, for example, undervoltage
or overtemperature occurs.
Green The DC input power is within range.
Blinking green The output power is out of range, for example, overvoltage,
overcurrent, or short circuit occurs.
PWR350D
Figure 7-8 shows the indicator of the PWR350D.
Figure 7-8 Indicator of the PWR350D
Table 7-7 Description of the PWR350D indicators
Name
Status Description
STATUS Off
l The input power is out of range, for example, no DC
input power, DC input overvoltage, and DC input
undervoltage.
l The output power is out of range, for example,
undervoltage or overtemperature occurs.
Green The DC input power is within range.
Blinking green The output power is out of range, for example,
overvoltage, overcurrent, and short circuit occurs.
PWR150A
Figure 7-9 shows the indicator of the PWR150A.