Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
NOTE
When inter-subrack protection
is configured, the ETH3
interface cannot be used for the
communication between the
master and slave subracks.
Connects a network
cable to a CRPC or ROP
board to achieve
communication with the
CRPC or ROP board.
Outputs single-subrack or
multi-subrack alarms to the
cabinet indicator interface to
light the corresponding
alarm indicators on the
cabinet.
NOTICE
The LAMP interfaces on the
EFI board provide 5 V power,
it is only used for the
indicators on a cabinet. It
cannot connect to an RJ45
cable intended for the
NM_ETH, ETH, ALMO, or
CLK interface; otherwise, the
EFI board, the connected test
instrument, or the equipment
will be damaged.
For information about the
interface cables, see 2.6.1
Cabinet Alarm Indicator
Cable.