47
1 PDF Circuit Breaker
Cabinet
Scenario
PDU PDF Circuit Breaker
N63B
2 x T32 subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
TN51PDU
1 x T32 subrack + 2 x
6800 subracks
DPD63-8-8 Configuration 1: 4 x 63 A (T32 subrack) + 4 x 32 A
(6800 subrack)
Configuration 2: 2 x 125 A (T32 subrack) + 2 x 63 A
(6800 subrack)
TN51PDU
1 x T32 subrack + 2 x
T16 subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
TN16PDU
1 x T32 subrack + 2 x
universal platform
subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
4 x T16 subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
TN16PDU
3 x T16 subracks + 1
x 6800 subrack
DPD63-8-8 Configuration 1: 6 x 63 A (T16 subrack) + 2 x 32 A
(6800 subrack)
Configuration 2: 2 x 125 A (2 x T16 subrack) + 2 x
100 A (1 x T16 subrack + 1 x 6800 subrack)
TN16PDU
3 x T16 subracks + 1
x universal platform
subrack
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
2 x T16 subracks + 2
x 6800 subracks
DPD63-8-8 Configuration 1: 4 x 63 A (T16 subrack) + 4 x 32 A
(6800 subrack)
Configuration 2: 2 x 125 A (T16 subrack) + 2 x 63 A
(6800 subrack)
TN16PDU
2 x T16 subracks + 2
x universal platform
subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
1 x T16 subracks + 3
x 6800 subracks
DPD63-8-8
Configuration 1: 2 x 63 A (T16 subrack) + 6 x 32 A
(6800 subrack)
Configuration 2: 2 x 100 A (1 x T16 subrack + 1 x
6800 subrack) + 2 x 63 A (2 x 6800 subrack)
TN16PDU
1 x T16 subracks + 3
x universal platform
subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A
4 x universal
platform subracks
DPD63-8-8
Configuration 1: 8 x 63 A
Configuration 2: 4 x 125 A