Check for Critical or Major Alarms on the Switch
4
Log in to the switch and run the display alarm active command to view the alarm status on the switch.
Check whether any critical or major alarms exist.
<HUAWEI> display alarm active | include Critical
A/B/C/D/E/F/G/H/I/J
A=Sequence, B=RootKindFlag(Independent|RootCause|nonRootCause)
C=Generating time, D=Clearing time
E=ID, F=Name, G=Level, H=State
I=Description information for locating(Para info, Reason info)
J=RootCause alarm sequence(Only for nonRootCause alarm)
3/Independent/2014-04-18 16:59:13-05:13/2014-04-18 16:59:17-05:13/0x502001/lin
kDown/Critical/End/OID 1.3.6.1.6.3.1.1.5.3 Interface 28 turned into DOWN state.(
AdminStatus 1,OperStatus 2,InterfaceName GigabitEthernet0/0/24)
4/Independent/2014-04-18 16:59:13-05:13/2014-04-18 16:59:17-05:13/0x502001/lin
kDown/Critical/End/OID 1.3.6.1.6.3.1.1.5.3 Interface 57 turned into DOWN state.(
AdminStatus 1,OperStatus 2,InterfaceName Vlanif4094)
The alarms on the switch are classified into critical, major, minor, and warning alarms. The critical and
major alarms must be handled immediately. Handle these alarms according to the Alarm Reference. If
the alarms cannot be cleared, contact your agent or Huawei enterprise technical support hotline.
If you have a network management system (NMS), check the alarms on the NMS.
For details, see the NMS product documents.

Other manuals for Huawei S5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S5700 Series and is the answer not in the manual?

Huawei S5700 Series Specifications

General IconGeneral
ModelS5700 Series
CategorySwitch
Power SupplyAC or DC
Fixed GE Ports24/48 (depending on model)
PoEAvailable on some models
Routing ProtocolsRIP, OSPF, BGP, IS-IS
ManagementSNMP, RMON, Web-based, CLI
Operating Temperature0°C to 45°C
VLAN4094
Dimensions (W x D x H)442.0 mm x 220.0 mm x 43.6 mm

Related product manuals