About This Guide

Packing List

Safety Guidelines

WARNING

Critical safety warnings regarding laser, power, and electrical hazards.

CAUTION

Safety cautions for environmental conditions, ESD protection, and equipment handling.

Site Environment

Installing the Chassis

Scenario 1: Desk Mounting

Details the procedure for placing the switch on a flat surface like a desk.

Scenario 2: Wall Mounting

Outlines the steps for securely mounting the switch onto a wall.

Scenario 3: Top Wall Mounting

Explains how to mount the switch on the top of a wall or surface.

Scenario 4: Cabinet;Rack Mounting

Instructions for installing the switch into a standard 19-inch cabinet or rack.

Installing a Power Module

Installing Cards

Connecting Cables

Logging In to the Switch for the First Time

Using the Web System for the First Login

Procedures for accessing and logging into the switch via its web interface.

Using the Console Port for the First Login

Instructions for connecting and logging in to the switch using a console port.

Obtaining Product Documentation and Technical Support

Trademarks and Permissions

Open Source Software Notice

Summary

About This Guide

Packing List

Safety Guidelines

WARNING

Critical safety warnings regarding laser, power, and electrical hazards.

CAUTION

Safety cautions for environmental conditions, ESD protection, and equipment handling.

Site Environment

Installing the Chassis

Scenario 1: Desk Mounting

Details the procedure for placing the switch on a flat surface like a desk.

Scenario 2: Wall Mounting

Outlines the steps for securely mounting the switch onto a wall.

Scenario 3: Top Wall Mounting

Explains how to mount the switch on the top of a wall or surface.

Scenario 4: Cabinet;Rack Mounting

Instructions for installing the switch into a standard 19-inch cabinet or rack.

Installing a Power Module

Installing Cards

Connecting Cables

Logging In to the Switch for the First Time

Using the Web System for the First Login

Procedures for accessing and logging into the switch via its web interface.

Using the Console Port for the First Login

Instructions for connecting and logging in to the switch using a console port.

Obtaining Product Documentation and Technical Support

Trademarks and Permissions

Open Source Software Notice

Overview

This document serves as a Quick Start Guide for the Huawei S2700, S3700, S5700, and S6700 Series Switches, detailing installation, cable connection, and initial login procedures. It emphasizes safety, proper environmental setup, and step-by-step instructions for various mounting scenarios and component installations.

Function Description

The Huawei S series switches are designed to facilitate network connectivity and management. They support various port speeds, including 2.5 Gbit/s, 5 Gbit/s, and 10 Gbit/s, depending on the Ethernet cable category used. The switches are capable of handling both AC and DC power supplies, with specific instructions provided for correct cable connections. Certain models offer a Mini USB port for onsite configuration, which takes precedence over the console port when both are connected. The switches support different heat dissipation modes, including forced, intelligent, or natural, to ensure optimal operation. They are designed to be integrated into existing network infrastructures, connecting to upstream network devices and operation terminals (PCs) via various cable types, including Ethernet, optical fiber, and console cables. The web-based configuration system allows for basic and optional settings, including VLAN isolation and interconnection, to tailor the switch's functionality to specific network requirements. For models that do not support web-based first login, a console port is available for initial configuration.

Usage Features

The switches offer flexible installation options, including desk mounting, wall mounting (top and side), and cabinet/rack mounting, to accommodate diverse deployment environments. For desk mounting, rubber pads are attached to the bottom, and an optional security lock can be installed to prevent theft. Wall mounting requires drilling holes and securing the switch with expansion bolts, with specific orientations recommended for certain models to ensure proper port access. Cabinet/rack mounting involves attaching mounting brackets to the chassis and securing it within a standard 19-inch cabinet, with considerations for cable management and clearance for heat dissipation. Guide rails or trays may be required for heavier chassis or specific cabinet configurations.

Component installation is straightforward, with detailed steps for power modules and cards. Power modules are generally hot-swappable, except for the 870 W PoE power module, and it is recommended to install two for enhanced power reliability. Cards are installed by loosening captive screws, turning ejector levers, pushing them into slots, and then securing them. Some cards are hot-swappable, while others require the switch to be powered off during installation. The guide highlights the importance of installing filler panels in vacant slots to maintain proper airflow and prevent dust ingress.

Initial login to the switch can be performed through either the web system or the console port. For web-based login, users can directly connect a PC to the ETH management interface or press and hold the MODE button to enter the initial configuration mode. The default IP address for the ETH management interface is provided, and users are guided to configure their PC's IP address within the same network segment. The web system offers a user-friendly interface for setting up management IP addresses, subnet masks, and user passwords, with a strong emphasis on password security. The Quick Config function simplifies VLAN isolation and interconnection settings. For console port login, a console cable connects the switch to a PC, and terminal simulation software is used with specified communication parameters to access the command-line interface.

Maintenance Features

The guide provides essential information for maintaining the switch's optimal performance and longevity. It stresses the importance of a suitable site environment, free from flammable gases, smoke, and excessive humidity, and emphasizes the need for good ventilation to prevent overheating. Dust-proofing and water-proofing measures are recommended for wall-mounted switches. Proper grounding is highlighted as a prerequisite for lightning protection, electromagnetic interference reduction, and electrostatic discharge prevention, as well as for PoE functionality.

For cable connections, specific recommendations are given for Ethernet cable categories based on port speed, ensuring reliable data transmission. Optical fibers must be used with optical modules, and attention to bend radius is advised to prevent damage. Power cables should be routed away from signal cables to minimize interference. The document also provides guidance on obtaining product documentation and technical support through Huawei's enterprise technical support website and community forums, ensuring users have access to comprehensive resources for troubleshooting and ongoing maintenance. The inclusion of safety guidelines, warnings, and cautions throughout the document underscores the importance of safe practices during installation and maintenance to protect both personnel and equipment. The guide also mentions the availability of an Open Source Software Notice, providing transparency regarding the software components used in the product.

Huawei S5731-S Specifications

General IconGeneral
ModelS5731-S
MAC Address Table Size16K
Power SupplyAC or DC
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Relative Humidity5% to 95% (non-condensing)
TypeEthernet Switch
Fixed Ports24 or 48 10/100/1000BASE-T ports
Uplink Ports4 x 10GE SFP+
Switching Capacity176 Gbps
Forwarding Rate96 Mpps
VLAN4096
Weight3.5 kg
Dimensions (W x D x H)442.0 mm x 220.0 mm x 43.6 mm