Working Principle
Figure 3-141 Working principle of the H802SHLB board
GE
H802SHLB
B
a
c
k
p
l
a
n
e
 
C
o
n
n
e
c
t
o
r
Control 
module
-48V
 DC 
power
Control 
board
Service 
signal
Control 
signal
Power 
signal
Clock 
signal
User sideBackplane
Power 
module
Voltage required 
by the board
Clock 
module
Clock required 
by the board
Interface 
module
Switching  module
Protection module
DC 
block
Protector
16*SHDSL
STU-R
 
The basic working principle of the H802SHLB board is as follows:
l The control module loads the board software, controls the running of the board, and
manages the entire board.
l The protection module protects and isolates the board from lightning strikes. The DC
block isolates the direct current. The protector protects the high voltage.
l The forwarding module processes the signals. After being processed by the control
module, the signals are transmitted to the backplane bus through the interface of the
backplane.
l The interface module inputs, outputs, and converts the signals.
l The power module supplies power to each functional module of the board.
l The clock module provides clock signals for each functional module of the board.
The service process is as follows:
l In the upstream direction, the interface module transmits subscriber line signals to the
forwarding module. The forwarding module reorganizes the cell flow into ATM/PTM
packets, encapsulates the ATM/PTM packets into IP packets, and performs CAR on the
IP packets. Controlled by the logical switch, the IP packets are transmitted to the
backplane bus through the backplane interface.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
3 Board
Issue 24 (2018-07-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.