Item SUN2000-20K
TL-M3
SUN2000-29.
9KTL-M3
SUN2000-30K
TL-M3
SUN2000-36K
TL-M3
SUN2000-40K
TL-M3
Output DC
component
(DCI)
< 0.5% of the rated output
Maximum
total
harmonic
distortion
AC THDi
< 3% under rated conditions. Single harmonic meets the VDE 4105 requirements.
Note a: Under the German VDE-AR-N-4105, Belgium C10/11, and Austrian TOR grid codes, the
SUN2000-30KTL-M3 has a maximum apparent power of 30000 VA and a maximum active power
(cosφ=1) of 30000 W.
Note b: The rated output voltage is determined by Grid Codes, which can be set on the SUN2000
app, SmartLogger, or management system.
Note c: You can determine whether to connect the N wire based on the application scenario. In
scenarios without N wires, set Output mode to Three-phase three-wire. In scenarios with N
wires, set Output Mode to Three-phase four-wire.
Protection
Item
SUN2000-20K
TL-M3
SUN2000-29.
9KTL-M3
SUN2000-30K
TL-M3
SUN2000-36K
TL-M3
SUN2000-40K
TL-M3
Overvoltage
category
PV II/AC III
Input DC
switch
Supported
Anti-islanding
protection
Supported
Output
overcurrent
protection
Supported
Input reverse
connection
protection
Supported
PV string fault
detection
Supported
DC surge
protection
Type II
AC surge
protection
Type II
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 10 Technical Specications