TRACKSO INSTALLATION GUIDE FOR HUAWEI
Brand: Huawei
Type: Solar On Grid String Inverter
Models: SUN2000-25KTL,30KTL,33KTL, 36KTL, 40KTL,55KTL, 60KTL
CONNECTION DIAGRAM
Locate communication terminals (RS485) as shown in the picture below. There are two connection terminals on the configuration
circuit board: RS485IN and RS485OUT (used for Daisy Chain connections)
Connection steps
Please unscrew the RS485 terminal as shown in A part of Figure H1.
Please make the connections from the Terminal Block to TrackSo IoT Gateway
as mentioned in Table HT1.
Provide 12V external supply to TrackSo IoT Gateway via 12V, 2A DC adaptor
provided in the package
Figure H1: Huawei SUN2000-33KTL, 36KTL,
40KTL,55KTL, 60KTL String Inverter
communicatio port
Table HT1 Huawei SUN2000-33KTL, 36KTL,
40KTL,55KTL, 60KTL RS485 connections with
TrackSo IoT Gateway
Note: RS485 Out- Used in case of Multiple
Inverter Connection (Daisy chain).
Huawei Pin no.
& Assignment
TrackSo Pin No.&
Assignment
1
RS485A
3
Data+
2
RS485A
RS485 Out
3
RS485B
4
Data-
4
RS485B
RS485 Out
Following Connection Diagram is valid for
HUAWEI SUN2000-33KTL, 36KTL, 40KTL,55KTL, 60KTL
Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-25KTL and is the answer not in the manual?

Huawei SUN2000-25KTL Specifications

General IconGeneral
Max. efficiency98.6%
European efficiency98.3%
Max. input voltage1100 V
MPPT operating voltage range200 V - 1000 V
Max. input current per MPPT26 A
Number of MPPTs2
Rated AC output power25000 W
Operating temperature range-25°C to +60°C
Max. apparent AC power27500 VA
Number of MPPT trackers2
Protection degreeIP65
Output Frequency50 Hz / 60 Hz
Cooling MethodNatural Convection
Rated AC voltage230 V / 400 V
Maximum Input Power37500 W
Maximum Output Power25000 W
Power Factor0.8 leading ... 0.8 lagging
CommunicationRS485

Summary

Huawei Inverter Connection Diagrams

SUN2000-33 KTL to 60 KTL RS485 Connections

Details RS485 connections for specific Huawei models via Table HT1.

SUN2000-25 KTL & 30 KTL RS485 Connections

Details RS485 connections for specific Huawei models via Table HT2.

Inverter Configuration and Setup

TrackSo IoT Gateway Default Settings

Configures Inverter ID, Baud Rate, Data Bits, Stop Bit, and Parity for the TrackSo gateway.

Huawei Inverter End Configuration

Guides on setting Date & Time, Baud Rate, Protocol, and Address using the Huawei APP.

Communication Card and Inverter Linking

Single Inverter Communication Setup

Covers terminal resistor settings for a solitary inverter connection.

Multiple Inverter Daisy Chain

Explains daisy chain connections for multiple inverters and terminal resistor usage.

TrackSo IoT Gateway Operation and Status

LED Status Indicators

Describes the meaning of Power, GSM, and COM TX/RX LEDs and their connection states.

Network Verification and Troubleshooting

Checking Network Status via SMS

Provides instructions for sending an SMS command to verify network status.

Event Log Analysis for Data Issues

Guides checking 'Event Ingestion Logs' for data problems and contacting support.

Related product manuals