EasyManuals Logo

Huawei SUN2000-25KTL User Manual

Huawei SUN2000-25KTL
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
5. To check the exact network status send the following message to mobile number of the device
SMS Command= *2222#<Stat.gsm>
IMEI
IMEI No. of the data logger (Device Key)
NW
Network
SIGN
Signal Strength out of 31
GPRS
CONT- connected , NC- not connected
PIP
Connected to TrackSo Server or not
CONT- connected, NC- not connected
LOG
no. of data points stored in devices incase of no interet
6. If the GSM light starts flashing 5 times then Login to www.trackso.in
with your Username/Password.
7. Click on ‘Units’ from the menu bar. You will be able to view your installed unit in the table as shown below.
8. Check if the Status becomes Receiveing for the relevant Unit.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-25KTL and is the answer not in the manual?

Huawei SUN2000-25KTL Specifications

General IconGeneral
Max. efficiency98.6%
European efficiency98.3%
Max. input voltage1100 V
MPPT operating voltage range200 V - 1000 V
Max. input current per MPPT26 A
Number of MPPTs2
Rated AC output power25000 W
Operating temperature range-25°C to +60°C
Max. apparent AC power27500 VA
Number of MPPT trackers2
Protection degreeIP65
Output Frequency50 Hz / 60 Hz
Cooling MethodNatural Convection
Rated AC voltage230 V / 400 V
Maximum Input Power37500 W
Maximum Output Power25000 W
Power Factor0.8 leading ... 0.8 lagging
CommunicationRS485

Related product manuals