SUN2000-(29.9KTL, 33KTL-A, 36KTL, 42KTL)
User Manual
10 Technical Specifications
Copyright © Huawei Technologies Co., Ltd.
96
Item
SUN2000-29.9
KTL
SUN2000-33K
TL-A
SUN2000-36K
TL
SUN2000-42K
TL
Full power
MPPT voltage
range
480800 V
480800 V
480800 V (380
V/400
V)/580850 V
(480 V)
580850 V
Rated input
voltage
620 V
620 V
620 V (380
V/400 V)/720 V
(480 V)
720 V
Maximum
input current
(per MPPT)
22 A
Maximum
short-circuit
current (per
MPPT)
30 A
Maximum
inverter
backfeed
current to the
PV array
0 A
Number of
inputs
8
Number of
MPP trackers
4
Note a: The minimum startup voltage of the SUN2000-36KTL is 200 V under the NB/T
32004 grid code.
Output
Item
SUN2000-29.9
KTL
SUN2000-33K
TL-A
SUN2000-36K
TL
SUN2000-42K
TL
Rated active
power
29,900 W
30,000 W
36,000 W
42,000 W
Maximum
apparent power
29,900 VA
33,000 VA
40,000 VA
47,000 VA
Maximum
active power
a
(cosφ = 1)
29,900 W
30,000 W
40,000 W (can
be set to 36,000
W)
47,000 W (can
be set to 42,000
W)

Other manuals for Huawei SUN2000-29.9KTL