EasyManua.ls Logo

HUGONG POWERTIG 300DPIII - Page 20

HUGONG POWERTIG 300DPIII
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
not work main control
board was broken
change main control board
connecting cable
drop up ( or break
off)
find where is cable break up
and connect it
7
Ammeter
no
display
Ammeter was
broken
change Ammeter
connecting cable
drop up ( or break
off)
find where is cable break up
and connect it
main control
board was broken
change main control board
8
arc is no
smooth
torch and
machine is fault
connected
check and correct by manual
Argon no pure use Argon with purity 99.99%
Tungsten
electrode is not
good or pinhead
is broken
change use correct tungsten
electrode
9
power
trip
first time power
on after long time
power was cut off
(over 2 days)
No fault, charge filter
capacitor of power main
circuit cause power trip,
switch on main power again.
10
others please contact with
manufacturer or supplier

Related product manuals