Place the inner Dataset® arm at downward position “4.” Tap the foot
pedal once or press “Enter.”
5
4
6
Move the inner Dataset® arm to downward position “5.” Tap the foot
pedal once or press “Enter.”
Move the inner Dataset® arm to downward position “6.” Tap the foot
pedal once or press “Enter.”
Return the inner Dataset® arm to the non-extended (short) position.
Position the calibration tool parallel to the spindle shaft on the hub using
the hub mounting slot as shown.
8
9
7
Place the inner Dataset® arm at the position “7.” Tap the foot pedal
once or press "Enter.”
Move the inner Dataset® arm to position “8.” Tap the foot pedal once or
press “Enter.”
Move the inner Dataset® arm to position “9.” Tap the foot pedal once or
press “Enter.”
If optional outer Dataset® arm is not installed, calibration is complete. If optional
outer Dataset® arm is installed, refer to “Outer Dataset® Arm,” page 11.
10 • Calibration Procedures DSP9600/9100 Service Manual