SERVICE MANUAL Form 5095T, 01-07
Supersedes Form 5095T, 05-06
DSP9600/9100 Balancer
© Copyright 2003 - 2007 Hunter Engineering Company

Other manuals for Hunter DSP9100

Question and Answer IconNeed help?

Do you have a question about the Hunter DSP9100 and is the answer not in the manual?

Hunter DSP9100 Specifications

General IconGeneral
BrandHunter
ModelDSP9100
CategoryScales
LanguageEnglish

Summary

Error Codes

Diagnostic Mode

Special Setup Items

Resetting All Setup Items to Default

Resets all setup items to factory defaults, stored in EEPROM.

Motor Test Mode

Tests motor functionality by adjusting duty cycle for clockwise/counter-clockwise rotation.

Auto-Spin Mode

Repeats balance spins automatically with adjustable delay between spins.

Motor PID Setting Mode

Switch Test

Verifies functionality of all keys and switches by requiring input for each.

Display Test

Activates all LEDs and tests display segments until spindle rotation or hood switch changes.

Configuration Jumpers

Identifying Balancer Model and Software Version

Changing Software (Replacing EPROM)

Procedure for safely removing and replacing the EPROM chip for software updates.

Skip Inner Arm Calibration and Calibrate Outer Arm

Allows calibration of only the outer Dataset arm, skipping the inner arm calibration process.

Calibration Procedures

Quick Cal Check

Attaches calibration weight and spins to check readiness or identify errors.

Balancer Calibration

Initiates the primary balancer calibration process using calibration weights.

Inner Dataset Arm Calibration

Detailed steps for calibrating the inner Dataset arm using a specific calibration tool.

Outer Dataset Arm Calibration

Detailed steps for calibrating the outer Dataset arm using a specific calibration tool.

Enabling/Disabling Inflation Station and Changing Units

Configures the inflation station and selects pressure units (kPa, PSI, Bar).

Inflation Station Calibration

Calibrates the inflation station, including zeroing pressure and optional reference gauge calibration.

Calibration Results

Status bits for the Balancer Spin Calibration

Interprets status bits indicating the success or failure of each stage of the spin calibration.

Status bits for the Inner Dataset Arm

Interprets status bits related to the inner Dataset arm calibration steps and sensor readings.

Status bits for the Outer Dataset Arm

Interprets status bits related to the outer Dataset arm calibration steps and sensor readings.