Status bits for the Inner Dataset® Arm
Status bits for the inner Dataset® arm have the same meaning as the bits shown on
a GSP9700.
Unused bits will be “0”. For example, if calibration passed, the bits will be “000011
111111”.
The bits are described below.
Bit 1 - This bit checks the readings in radial steps 2 and 3 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® diameter sensor circuit or the correct
calibration sequence was not followed.
Bit 2 - This bit checks the readings in radial steps 1 and 2 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® diameter sensor circuit or the correct
calibration sequence was not followed.
Bit 3 - This bit checks the readings in radial steps 1 and the initial
storing of the home settings of the inner Dataset® calibration. If
this bit fails, there is something wrong with the inner Dataset®
diameter sensor circuit or the correct calibration sequence was
not followed.
Bit 4 - This bit checks the readings in radial steps 5 and 6 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® diameter sensor circuit or the correct
calibration sequence was not followed.
Bit 5 - This bit checks the readings in radial steps 4 and 5 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® diameter sensor circuit or the correct
calibration sequence was not followed.
Bit 6 - This bit checks the readings in lateral step 1 and the initial
storing of the home settings of the inner Dataset® calibration. If
this bit fails, there is something wrong with the inner Dataset®
distance sensor circuit or the correct calibration sequence was
not followed.
NOTE: Press “Next” to show remaining bits (2b). The first bit on the
right will be bit 7.
Bit 7 - This bit checks the readings in lateral step 1 and 2 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® distance sensor circuit or the correct
calibration sequence was not followed.
Bit 8 - This bit checks the readings in lateral step 2 and 3 of the inner
Dataset® calibration. If this bit fails, there is something wrong
with the inner Dataset® distance sensor circuit or the correct
calibration sequence was not followed.
NOTE: Turn the “D” knob to advance to next diagnostic variable.
14 • Calibration Results DSP9600/9100 Service Manual