Error Codes
1. Spindle Encoder Timeout - Timer overflowed during a spin. This should
never happen if spindle is rotating.
2. Excessive Time to Spin Up - Too long to reach minimum RPM during spin
up.
3. Forward Rotation Not Detected - Exceeded time limit to rotate spindle
in the correct direction at the start of a spin.
4. Motor Drive Fault Detected - DC drive box signaled an error condition.
5. Unexpected Reverse Rotation - Spindle rotating in the wrong
direction. This error may occur instead of “Loose” error if wing nut is loose or
there is no wheel on the spindle.
6. No Home Pulse Detected - Home pulse never detected during a full
revolution.
7. No Expected Home Pulse - Home pulse did not occur at expected
spindle encoder count.
8. Unexpected Home Pulse - Home pulse detected at unexpected spindle
encoder count. Multiple home pulses.
9. Erratic Spindle Encoder - Incorrect spindle encoder “A” and “B” phases.
10. Left Force Transducer Temperature - Left transducer temperature sensor
not functioning.
11. Right Force Transducer Temperature - Right transducer
temperature sensor not functioning.
12. Balancer Cal Recall Error - Error reading balancer calibration data from
EEPROM.
13. Balancer Cal Store Error - Error storing balancer calibration data to
EEPROM.
14. Dataset® Arm Cal Recall Error - Error reading Dataset® arm
calibration data from EEPROM.
15. Dataset® Arm Cal Store Error - Error storing Dataset® arm calibration data
to EEPROM.
16. Setup Recall Error - Error reading setup data from EEPROM.
17. Setup Store Error - Error storing setup data to EEPROM.
18. Wheel Recall Error - Error reading wheel data from EEPROM.
19. Wheel Store Error - Error storing wheel data to EEPROM.
20. Multiple Recall Errors - More than one error reading data from
EEPROM at boot up. This always happens after first boot up with new DSP
board. Need to save setup and all calibrations.
21. Inflation Station Cal Store Error - Error storing Inflation Station
calibration to EEPROM.
22. Inflation Station Cal Recall Error - Error reading Inflation Station
calibration data from EEPROM.
23. PID Constant Recall Error - Error reading motor control constants from
EEPROM.
24. PID Constant Store Error - Error storing motor control constants to
EEPROM.
DSP9600/9100 Service Manual Error Codes • 1