Attach the Inflation Station hose to the tire that was measured in the previous step,
and press “Enter.” The difference between the measured pressure and the dialed in
number must be within 7 PSI or the calibration will fail.
NOTE: If you wish to skip the optional reference gauge calibration,
leave the dialed in pressure at zero, keep the inflation hose
in the home storage position, and press “Enter.”
Display reads “Rdy Inf” if calibration passed.
Press the “Setup/Cal” button to exit calibration mode.
Calibration Results
The DSP9600/DSP9100 uses GSP9700 style calibration status bits. “0” bit indicates
a failure. “1” bit indicates a pass.
Six bits (counting from the right) are displayed on the left and right weight
digits.
Press “Next” key to advance.
The DSP9600 does not have enough digits to display the entire cal result for the
inner Dataset® arm cal and spin cal.
The first group of 6 bits (counting from the right) is displayed on the left
and right weight digits first. The diagnostic variable number will be “1A”
or “2A” for the first 6 bits.
Press “Next” key to show the second group of the cal result bits. The
diagnostic variable number will be “1b” or “2b” for the next 6 bits.
Turn the “D” knob to advance to next diagnostic variable.
6 5 4 3 2 1 12 11 10 9 8 7
SECOND GROUP OF DIAGNOSTIC BITS FIRST GROUP OF DIAGNOSTIC BITS
Example above shows a Spin cal bit 5 failure.
12 Calibration Results DSP9600/9100 Service Manual