Special Setup Items
Hold Right and Left Split Weight® keys during power up.
Press Cal/Setup key to enter Setup. Three new items will be available in addition to
the regular setup items.
Weight rounding value (0.25, 0.01, 0.05 oz).
Weight blind value (0.29, 0.58, 0, 0.15 oz).
Language (Domestic, English Int., German, Spanish LA, Spanish).
Resetting All Setup Items to Default
To automatically reset all setup items to factory defaults hold down “Setup/Cal” key
during power up.
Settings will be stored in EEPROM memory and will remain defaulted when power is
turned off.
Motor Test Mode
Hold Static/Dynamic key and Ounces/Grams key during power up.
Motor duty cycle is shown on “W” digits (50% at startup). Lower the hood and press
Start key. The motor should remain stopped or begin to slowly rotate in either
direction.
Use the “W” dimension knob to change the duty cycle. Duty cycles greater than 50%
cause the motor to spin clockwise (direction of balance spin). Less than 50% duty
cycle spins the motor counter-clockwise.
Balancer will not function as a normal balancer while in motor test mode. Turn power
off and back on to exit this test.
Auto-Spin Mode
Hold down Left Split Weight® and Static/Dynamic key at power up.
Continuously repeats balance spins, with an adjustable delay between each spin.
Turn “W” dimension knob to adjust time between spins (in seconds).
Spin count is shown in “A” digits.
Balancer will not function as a normal balancer while in motor test mode. Turn power
off and back on to exit this test.
DSP9600/9100 Service Manual Special Setup Items • 3