EasyManua.ls Logo

Husky H15123TK - Page 13

Husky H15123TK
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
ASSEMBLY
WARNING:
Do not attach any tools to the open end of the hose until
start-up has been completed.
ATTACHING HOSE
See Figure 6.
Make sure the air compressor is off and unplugged.
Rotate pressure regulator knob fully counterclockwise.
Insert the hose into the quick coupler already installed
on the compressor (Fig. 6).
Firmly grasp the open end of the hose; hold facing
away from yourself and others.
BREAKING IN THE PUMP
See Figure 4 - 5.
Check and tighten all bolts, fittings, etc.
Turn the pressure regulator knob fully clockwise to
open the air flow.
Place the switch in the OFF position and plug in the
power cord.
Open the drain valve completely.
Turn the air compress ON ( l ) and run the air
compressor for 10 minutes to break in pump parts.
Place the switch in the OFF position.
Close the drain valve.
ASSEMBLY
TANK
PRESSURE
GAUGE
QUICK
COUPLER
PRESSURE
REGULATOR
KNOB
SAFETY
VALVE
ON/OFF
SWITCH
Fig. 4
DRAIN VALVE
Fig. 5
QUICK
COUPLER
HOSE
Fig. 6
REGULATOR
PRESSURE
GAUGE

Related product manuals