Parameter Programmed Report
Min Max
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
0 sec 59 min 59 sec
0 sec 30 min 59 sec
0 sec 59 min 59 sec
57º
61º
0=disable or 1=enable
0=Celsius or 1=Fahrenheit
0=Relays fail OPEN
2=Relays fail CLOSE
3=Duty cycle
1 min 59 hour 59 min
1 min 59 hour 59 min
0=disable
1=System run time
2=Compressor run time
1=Electric
2=Off-cycle
3=reverse cycle
10 min 71 hour 59 min
10 min 71 hour 59 min
1 min 4 hour 59 min
-40ºC (-40ºF) 40ºC (104ºF)
0 sec 59 min 59 sec
0=disable or 1=enable
0=disable or 1=enable
0=disable
1=Evap. Sensor
2=Control Sensor
3=Digital Switch (close)
0=disable or 1=enable
0ºC (0ºF) 40ºC (72ºF)
0 sec 59 min 59 sec
0 sec 59 min 59 sec
0=disable or 1=enable
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
-40ºC (-40ºF) 40ºC (104ºF)
1ºC (2ºF) 10ºC (18ºF)
0 min 4 hour 59 min
0 min 17 hour 59 min
0 min 17 hour 59 min
0=disable or 1=enable
0.2 sec 24.9 sec
0=disable or 1=enable
0.4 sec 24.8 sec
0=display temperature read
1=lock the display on temp.
2=display DF
5 sec 59 min 59 sec
-40ºC (-72ºF) 40ºC (72ºF)
0 min 1 hour 59 min
0=disable or 1=enable
099
0=disable or 1=enable
0 min 17 hour 59 min
0=disable or 1=enable
5 sec 59 min 59 sec
0 sec 59 min 59 sec
Parameter Description Value
1
Freezer Cut-in warm
42°F
2
Freezer Cut-out warm
36°F
3
Freezer Cut-in cold
36°F
4
Freezer Cut-out cold
30°F
5
Compressor ON time delay at Controller Power Up 0 min 30 sec
6
Compressor Minimum (ON) time 1 min 0 sec
7
Compressor Minimum (OFF) time 2 min 0 sec
8
Potentiometer off position
10º
9
Potentiometer on position
15º
10
On-Off logical function
1
11
Controller Operation Temperature Units
1
12 Sensor failure mode
(compressor and fan relay
failure mode)
3
13
Compressor On Time if Sensor failed 0 hour 45 min
14
Compressor Off Time if Sensor failed 0 hour 6 min
15 Defrost Function 1
16 Defrost Method 2
17
Time to first defrost(Initial frost build time) 2 hour 0 min
18
Time to subsequent defrost 4 hour 0 min
19
Defrost duration Time (failsafe) 0 hour 26 min
20
Defrost Termination temperature
54°F
21
Drip time 0 min 0 sec
22
Defrost Cycle at power on
0
23
Evaporator Temp. Sensor
1
24 Defrost Termination Method 1
25
Temperature Initiated Defrost Function
0
26
Temperature Initiated Defrost (T = Tspace-Tevap.)
2°F
27
Temperature Initiated Defrost Time Delay 3 min 0 sec
28 Temperature Initiated Defrost Time Delay
After Defrost
59 min 0 sec
29
Temperature Alarm Enable
1
30
High Temperature Alarm - Warm
48°F
31
Low Temperature Alarm - Warm
34°F
32
High Temperature Alarm - Cold
40°F
33
Low Temperature Alarm - Cold
28°F
34
Temperature Alarm Differential
4°F
35
Temperature Alarm Time delay 0 hour 20 min
36
Temperature Alarm Disable Time after Start Up 3 hour 0 min
37
Temperature Alarm Delay after Defrost 1 hour 0 min
38
Buzzer Function
1
39
Buzzer Period 24.9 sec
40
Led Alarm Function
1
41
Led Alarm Period 2.0 sec
42 Defrost Display Lock
(display indication during defrost)
1
43
Sensor Fault Monitoring Time 1 min 0 sec
44
Display Temperature Offset
0°F
45
Display Unlock Time 0 hour 45 min
46
Show Parameter Code Number
1
47
Parameter Code Number
11
48
Maximum Compressor Run Function
0
49
Maximum Compressor Run Time 2 hour 0 min
50
Defrost Heater Duty Cycle Function
0
51
Heater On Time 1 min 0 sec
52
Heater Off Time 0 min 30 sec