5-8 INSTALLATION
P/N 0515258_N U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
Electrical Data
Note: These are rated values for individual components and should not be added together to deter-
mine total merchandiser electrical load.
SHM-3 SHM-4
Number of Fans – 5W 2 2
Amperes Watts Amperes Watts
Evaporator Fans
115V 60Hz Standard 0.6 10 0.6 10
Condensate Pan Heaters (115V) 8.3 1000 3 350
Condensing Unit
(208/230V, 1Ph, 60Hz) Standard
SHM-3
Compressor LRA 39
Compressor RLA 7.9
SHM-4
Compressor LRA 48
Compressor RLA 9.5
Product Data
AHRI Total Display Area
1
(Sq Ft/Case) SHM-3 6.1 ft
2
/case (0.584 m
2
/case)
SHM-4 8.1 ft
2
/case (0.752 m
2
/case)
1
Computed using AHRI 1200 standard methodology:
Total Display Area, ft
2
[m
2
] / Unit of Length, ft [m]
A-6 APPENdIx A TEChNICAL dATA