UST CC 6-T Manual
4 - 26
Setting 2, S-curve type
If no special reuirement is raised for acceleration/deceleration, it is suggested to
set this parameter to “1”.
98. Setting of 1 acceleration/deceleration time constant
Format default value: 1, unit: milli-second ms
Setting range: 23 ms.
99. Setting of acceleration/deceleration time constant
Format default value: 1, unit: milli-second ms
Setting range: 23 ms
100. Setting of acceleration/deceleration time constant
Format default value: 1, unit: ms
Setting range: 23 ms, suggest to set both and to 1.
101. Setting of MP acceleration/deceleration time
Format default value: 64, unit: ms
Setting range: 23 ms.
Setting of motor acceleration/deceleration time in handwheel mode, suggested
setting value is 15.
102. Retention
103. Setting of spindle voltage ero correction value
Format . default value: , unit: mv
Range: -..
Adusts spindle voltage ero effective in open-circuit.
If system output is about --.1 at system speed S, then voltage ero parameter
is: 2 .1 1/24. Adust output voltage to be as close to as
possible at system speed S. This parameter is normally set to 21.
: For adusting spindle speed by inverter
1. First adust this parameter so that output voltage is closest to when
the rpm is ero.