6 Error Message
6 - 7
Error Code Details Causes
There have some error in programming occurs when
executing the program in AUTO mode.
C
Error of copied segment in the program; cause for the error
may be one of the following:
1. Non-existence of the source program.
2. Starting line-no. > Ending line-no. in the source
program
3. Starting line-no. > total line-number of the source
program
4. Ending line-no. > total line-number of the source
program
5. Missing program number in the pasting target.
6. Starting line-no. of the pasting target > total line-
number.
7. Memory is full when the pasting content has not been
fully pasted.
8. Source program = pasting target program no.; and,
starting line of source program <= starting line no. of
pasting target <= ending line no. of source program.
M
Trigger C25 segment data retrieval error: cannot find
initial address of specified segment.
T Failure in finding initial address of specified program.
Q
M95Qxxx error (QA is out of 0 127, or QA specified
program does not exist).
L
M99 jump-back program error (G10P301 specified line-no.
error).
18
P Empty CALL in sub-program. (G60 G63)
Message
Program ending is wrong.
Remedy:
1. Check the ending of the program and add M02 or M03 segment.
2. G80 is not filled for the drilling, tapping command ending area.
3. Check the program for excessive size.
4. Check for any error in the segment content and in serial setting (N) of the specified
segment.