7 - 6
MCM
No.
Factory
Default
Setting
Unit Description Setting
8=V-axis, 9=w-axis, 256= non-stop mode in a single block
502 0 Accel/Decel mode,0=exponential,1=linear,2=S” curve
Home command mode setting.
BIT0 = 0 , X axis find Home grid available,
= 1 , no need to find.
BIT1 = 0 , Y axis find Home grid available,
= 1 , no need to find.
BIT2 = 0 , Z axis find Home grid available,
= 1 , no need to find.
BIT3 = 0 , A axis find Home grid available,
= 1 , no need to find.
BIT4 = 0 , B axis find Home grid available,
= 1 , no need to find.
BIT5 = 0 , C axis find Home grid available,
= 1 , no need to find.
BIT6 = 0 , U axis find Home grid available,
= 1 , no need to find.
BIT7 = 0 , V axis find Home grid available,
= 1 , no need to find.
503 0
BIT8 = 0 , W axis find Home grid available,
= 1 , no need to find.
504 100 msec G00 Linear accel./decel. Time, 4~512 ms
505 100 msec G01 Linear accel./decel. Time, 10~1024 ms
506 100 msec Accel/Decel time when in G99 mode (mm/rev)
507 100 msec Time Setting for spindle acceleration
508 0
System Reserved
509 4096 pulse Spindle encoder resolution (pulse/rev)
510 3000 rpm Max. spindle rpm at 10 volts
511 0 v
Spindle voltage command zero drift correction (open
circuit)
512 0
Spindle voltage command acce/dece slope correction (open
circuit)
513 0 rpm
Spindle RPM correction (based on feedback from the
encoder)
514 0 Start number for program block number generation
515 0 Increment for program block number generation
516 1 Denominator of feed-rate when in MPG test mode
517 1 Numerator of feed-rate when in MPG test mode
518 0 MPG direction
519 64 ms Set Acceleration/Deceleration Time for MPG (4~512)
520 38400 RS232 Baud rate, 38400, 19200 / EVEN /2 Bit
521 0
Setting whether R000~R99 data in PLC are stored when
power is cut off. 0=NO, 256=YES
522 0 pulse Servo Error Counter
523 0 Radius/Diameter Programming mode
524 0 0=Metric mode, 25400=inch mode mcm541=0,1
525 3 Error in Circular Cutting, ideal value=1
526 0
Pulse settings
0: pulse + direction 1: +/- pulse 2: A/B phase
527 1000 Setting G01 speed value at booting
528 0 Setting tool compensation direction =1 FAUNC, =0 HUST
529 0
It is used for adjusting the G01’s acceleration/deceleration time
when the acceleration/deceleration type is set to an S” curve.