HUST CNC H6D-T Manual
7 - 42
621. Software OT Limit in (+) Direction, X-axis. (Group 2)
622. Software OT Limit in (+) Direction, Y-axis. (Group 2)
623. Software OT Limit in (+) Direction, Z-axis. (Group 2)
624. Software OT Limit in (+) Direction, A-axis. (Group 2)
625. Software OT Limit in (+) Direction, B-axis. (Group 2)
626. Software OT Limit in (+) Direction, C-axis. (Group 2)
627. Software OT Limit in (+) Direction, U-axis. (Group 2)
628. Software OT Limit in (+) Direction, V-axis. (Group 2)
629. Software OT Limit in (+) Direction, W-axis. (Group 2)
Format Unit: mm/min (Default=9999.999)
In PLC when C10 1, it detects unit 2 software’s range limit.
Set the software over-travel (OT) limit in the positive (+) direction, the setting
value is equal to the distance from positive OT location to the machine origin
(HOME).
MCM# 630~640 System Reserved
641. Software OT Limit in (-) Direction, X-axis. (Group 2)
642. Software OT Limit in (-) Direction, Y-axis. (Group 2)
643. Software OT Limit in (-) Direction, Z-axis. (Group 2)
644. Software OT Limit in (-) Direction, A-axis. (Group 2)
645. Software OT Limit in (-) Direction, B-axis. (Group 2)
646. Software OT Limit in (-) Direction, C-axis. (Group 2)
647. Software OT Limit in (-) Direction, U-axis. (Group 2)
648. Software OT Limit in (-) Direction, V-axis. (Group 2)
649. Software OT Limit in (-) Direction, W-axis. (Group 2)
Format . Unit: mm/min (Default=-9999.999)
In PLC when C10 1, it detects unit 2 software’s range limit.
Fig 7.5
Machine Origin
(Home)
Software OT Limit
(MCM#581~ #649)
Emergency Stop
5~10 mm each
Actual Hardware Limit
Emergency Stop