9 Appendix B – PC On-line Operation
9 - 5
run the command G10 P600 L02 to burn the Uploaded MCM parameter data
onto the FLASHROM.
4. As depicted in Fig. 901, after entering the G10 P600 L02 command in the entry
area, press MDIGo to complete the burn movement.
9.1.4 Transfer MCM Data from CNC Controller to PC
Movement program:
1. The controller is not in a program execution state (where S080=0).
2. When S080 is “ 0 ”, the controller is stand-by.
3. On PC side, make sure the transmission is ready to transmit.
Baud Rate should be correct when you execute HCON.exe (See section 10, Chapter
9 ). After entering Data Transmission Mode ( FileSvc ),
(1) Select “ Recv File fm CNC : TYPE >>> ”
(2) Select “ 2:MCM ”
(3) Press “ Recv In
(4) After the confirmation of the file content, press “ Save File
Note:
When the program is in execution (S080=1), you must stop for S080 turning “0” to re-
operate the step 3 & 4.
9.1.5 Transfer Data Variable from PC to CNC controller
Movement program:
1. The controller is not in a program execution state (where S080=0).
2. On the PC end, verify that the PC computer end is ready to carry out the program
transmitting movement.
Execute HCON.exe to ascertain that there is no error in the communication
protocol
Upon entering the data transmission mode ( FileSvc ),
(1) Select “Send File To CNC : TYPE >>> ”
(2) Select “ 9:Var ” (Transmitting the variable data to the controller).
(3) Press “ Open File ” to select the variable file to be transmitted.
(4) Upon ascertaining the file content, press Send Out .
The computer automatically uploads the data.
Caution: When the controller is running program (where S080=10, there is a need to wait for
the program execution to stop (where S080=0) before running steps (3) & (4).
9.1.6 Transfer Data Variable from CNC controller to PC
Movement program:
The controller is not in a program execution state (where S080 = 0).