9 Appendix B – PC On-line Operation
9 - 7
9.1.8 Transfer LCD Screen Display Data from PC to CNC
Movement program:
1. The controller is not in a program execution state (where S080 = 0).
2. On the PC end, verify that the PC computer end is ready to carry out the program
transmitting movement.
Execute HCON.exe to ascertain that there is no error in the communications
protocol.
Upon entering the data transmission mode ( FileSvc ),
(1) Select “Send File To CNC : TYPE >>>
(2) Select “ 4:CRT ” (Transmitting the screen data to the controller)
(3) Press “ Open File ” to select the screen file to be transmitted.
(4) Upon ascertaining the file content, press Send Out .
The computer automatically uploads the data.
Caution:
1. When the controller is running programs (where S080=1), there is a need to wait for
the program execution to stop (where S080=0) before running steps (4).
2. After uploading the screen data, there is no need to execute the burn command, as
the system automatically uploads the data onto the Flash-ROM.
9.1.9 Transfer Controller System Data from PC to CNC
Movement program:
1. The controller is not in a program execution state (where S 080 = 0).
2. On the PC end, verify that the PC computer end is ready to carry out the program
transmitting movement.
Execute HCON.exe to ascertain that there is no error in the communication
protocol.
Upon entering the data transmission mode ( FileSvc ),
(1) Select “Send File To CNC : TYPE >>>
(2) Select “ 5:SYS ” (Transmitting the system data to the controller)
(3) Press “ Open File ” to select the system file to be transmitted.
(4) There is a need to check“ w2FLASH ”to activate the burn motion.
(5) Upon ascertaining the file content, press Send Out
The computer automatically uploads the data.
Caution:
1. When the controller is running programs (where S080=10, there is a need to wait for
the program execution to stop (where S080=0) before running step (5).
2. Upon uploading the system data, there is no need to execute the burn command, as
the system automatically uploads the data onto the Flash-ROM.
3. Upon completing transmitting the system file, make sure that the screen is
prompted with “Data Loading Ok!”, otherwise it indicates that the system file has
not been transmitted successfully.