9 - 8
9.1.10 Transfer function tables from PC to CNC controller
Movement program:
1. The controller is not in a program execution state (where S080 = 0).
2. On the PC end, verify that the PC computer end is ready to carry out the program
transmitting movement.
Execute HCON.exe to ascertain that there is no error in the communication
protocol.
Upon entering the data transmission mode ( FileSvc ),
(1) Select “Send File To CNC : TYPE >>>
(2) Select “ 8:PTN ” (Transmitting the entry column data to the controller).
(3) Press “ Open File ” to choose the entry column file to be transmitted.
(4) Upon ascertaining the file content, press Send Out
The computer automatically uploads the data.
Caution:
1. When the controller is running programs (where S080=1), there is a need to wait for
the program execution to stop (where S080=0) before running steps (4).
2. Upon uploading the screen data, there is no need to execute the burn command, as
the system automatically uploads the data onto the Flash-ROM.
9.1.11 PC to Controller (ARM)
Movement program:
1. The controller is not in a program execution state (where S080 = 0).
2. On the PC end, verify that the PC computer end is ready to carry out the program
transmitting movement.
3. Execute HCON.exe to ascertain that there is no error in the communications
protocol
4. Upon entering the data transmission mode ( FileSvc ),
(1) Select “Send File To CNC : TYPE >>>
(2) Select “ C:ARM ” (Transmitting the CPU data to the controller)
(3) Press “ Open File ” and choose the CPU file to be transmitted.
(4) After verifying the file content, press Send Out .
The computer automatically uploads the data.
Caution:
1. When the controller is running programs (where S080=1), there is a need to wait for
the program execution to stop (where S080=0) before running step (5).
2. Upon uploading the ARM data, there is a need to restart the computer in order to
operate the system normally.