10 Appendix C Method for using the most often used G10 command
10 - 3
Take the following precautions when using G10 to set the work origin:
a. Do not add P__ when using G10 to set the work coordinates
system, or it will become a tool length (displacement)
compensation.
b. Use the same method to enter work coordinates system G55~G59.
The difference is to replace G54 with G55~G59 in step 4. If any of
the work coordinates system G54~G59 is not explicitly indicated
in the steps, the work origin will be entered into the work
coordinate system that is effective at that time.
c. The G10 method can also be used to enter the work coordinates in
a program.
d. The machine coordinates of the origin of the G54~G59 work
coordinates selected by the G10 method will be entered into MCM
parameters (see 3.25).
(2) G10 P600 L02 burning MCM parameters
EX: If parameters are not burnt into FLASHROM after altering machine
parameters or transmitting MCM parameters, you may press and hold
the Burn Parameter key in the parameter screen to burn the
parameters to the controller; you may alternatively edit and enter
G10 P600 L02 command in MDI mode, and then press the START
key to complete the operation of Parameter Burning. The burning is
successful when the controller screen shows the message Data
Loading Ok!.
(3) G10 P600 L03 burn the PLC file
EX: When using the HCON software to transmit a PLC file without
check-selecting W2Flash , you may enter G10 P600 L03 in the
MDI mode upon completion of the transmission and then press the
START key to complete the operation for burning the PLC. The
burning is successful when the controller screen shows the message
Data Loading Ok!.
(4) G10 P600 L05 burn the system file
EX: When using the HCON software to transmit a system file without
check-selecting W2Flash , you may enter G10 P600 L05 in the
MDI mode on completion of the transmission and then press START
key to complete the operation for burning the PLC. The burning is
successful when the controller screen shows the message Data
Loading Ok!.
(5) G10 P1000: Loading parameters into memory from FLASHROM