HUST CNC H6D-T Manual
10 - 4
EX: After replacing the main PCB of the controller, insert the
FLASHROM onto the new PCB and enter G10 P1000 command in
the MDI mode, then press START to save the parameters which are
stored in the FLASHROM into the memory.
(6) G10 P2000: Delete the current program
EX: The current Program No. is: No. 1 program , entering G10
P2000 in the MDI mode and pressing the START key will delete this
No.1 program.
(7) G10 P2001: Delete all programs
EX: Edit and input G10 P2001 in the MDI mode, then press START key
to delete all the programs in the controller, including the [???]
and user process programs.
This command can be used to delete all programs in the controller.
Special cautions shall be taken when using this command since the
operation is non-reversible. Please backup the program data and
substitute program data before using this command.
(8) G10 P1999 L9999: clear the controller to return to default settings
EX1: In case of anomalies in screen display, parameter display, or machine
operation after altering the controller data (compared to the status
before the alteration), it is suggested to perform this command in the 2
ways as described above, and clear the controller to its default settings
followed by re-loading the data.
EX2: In case of anomalies in user variables and machine parameters after
linking with HCON software (the value becomes very large, or most
of the values are identical), it is suggested to perform this command in
the 2 ways as described above, and clear the controller to its default
settings followed by re-loading the data.
Note: The above operations are non-reversible and shall be used with
care. Suggest that you should make backup and substitute data
before performing the operation.