Overview:
The HydroCheck HC6000v2 Electronic Sump Pump Float Switch with Hi-Lo Dual Sensors and Built-in Alarms is a universal
float switch that works with all types of sump pumps. The pump cycle will start when water reaches the Hi-Sensor (Red) and
stop when water drops below the Lo-Sensor (Black). Easily achieve your desired cycle length by adjusting the distance
between the sensors. See the Troubleshooting section for Smart Button, LED and Alarm specifications. Not rated for outdoor
use.
READ PRIOR TO INSTALLATION:
1. The “piggyback plug” attached to the mechanical float switch cannot be used with the HC6000v2. It must be disconnected
and remain disconnected.
2. If your sump pump has internal float switch wiring, i.e. does not have a “piggyback plug”, then you must secure the float in
an upward position as if the pit were full. This assures that the internal switch is always closed and that
the pump is enabled.
3. Pits that receive water from a water softener or that have high mineral/iron content require an alternative installation
method. Use the HydroCheck Sensor Installation Kit to ensure maximum reliability in all installation applications.
Visit our website www.hydrocheckproducts.com for more information.